Technické dokumenty
Špecifikácie
Brand
ABUS Security-CenterPočet kabelově zapojených zón
8
Maximální počet uživatelských kódů
16
Napájecí napětí
230V
Hloubka
85 mm
Výška
235 mm
Šířka
235mm
Krajina pôvodu
China
Podrobnosti o výrobku
Terxon SX Alarm Panel
The Terxon SX alarm panel is an entry level alarm center for smaller properties. 9 zones ensure gap-free security. The system has 8 freely programmable zones for wired detectors. Zone 9 is the sabotage zone. Only NC detectors can be connected. The type of wiring is left up to you (NC or DEOL sabotage contact in series or as its own zone). The signal generator has its own (reserved) sabotage zone on the motherboard. Three 500mA transistor switching outputs that can be assigned to a certain event (alarm, fire or robbery) are located on the motherboard. the Terxon SX can also be expanded with a relay board (8 x 1A relays).,Supplied with a white LCD control unit, which allows the system to be quickly and conveniently programmed or activated/deactivated. You can connect 3 additional control units. The connection is made via 4-wire bus wiring.,16 users with their own codes and chip keys can operate the system.
8 alarm zones for NC contacts or differential signalling zone
1 sabotage zone
3 transistor outputs max. 500mA
8 transistor outputs max. 50mA
Integrated power pack 230VAC/12VDC (1A)
Optional pluggable relay module Integrated buzzer for alarm (in control unit)
Informácie o zásobách sú dočasne nedostupné.
Skúste to znovu neskôr.
P.O.A.
1
P.O.A.
1
Technické dokumenty
Špecifikácie
Brand
ABUS Security-CenterPočet kabelově zapojených zón
8
Maximální počet uživatelských kódů
16
Napájecí napětí
230V
Hloubka
85 mm
Výška
235 mm
Šířka
235mm
Krajina pôvodu
China
Podrobnosti o výrobku
Terxon SX Alarm Panel
The Terxon SX alarm panel is an entry level alarm center for smaller properties. 9 zones ensure gap-free security. The system has 8 freely programmable zones for wired detectors. Zone 9 is the sabotage zone. Only NC detectors can be connected. The type of wiring is left up to you (NC or DEOL sabotage contact in series or as its own zone). The signal generator has its own (reserved) sabotage zone on the motherboard. Three 500mA transistor switching outputs that can be assigned to a certain event (alarm, fire or robbery) are located on the motherboard. the Terxon SX can also be expanded with a relay board (8 x 1A relays).,Supplied with a white LCD control unit, which allows the system to be quickly and conveniently programmed or activated/deactivated. You can connect 3 additional control units. The connection is made via 4-wire bus wiring.,16 users with their own codes and chip keys can operate the system.
8 alarm zones for NC contacts or differential signalling zone
1 sabotage zone
3 transistor outputs max. 500mA
8 transistor outputs max. 50mA
Integrated power pack 230VAC/12VDC (1A)
Optional pluggable relay module Integrated buzzer for alarm (in control unit)