Technické Dokumenty
Špecifikácie
Brand
FlukeČíslo modelu
116/62 MAX+
Typ produktu
Sada multimetrů
Použití
Industrial
Obsah sady
Infračervené teploměry, Sondy, Pouzdro, Multimetr
Typ sady
Multimeter Kit
Normy/schválení
EN/IEC 610101: 2001, UL, CSA, EN 608251 Class II, FDA, CE, VDE, TUV
Krajina pôvodu
Malaysia
Podrobnosti o výrobku
This multimeter kit provides a portable toolkit for industrial electrical measurement and temperature checks in professional environments. Supplied with infrared thermometers, probes, a protective case and a Compact digital multimeter, it is intended for field and workshop use where voltage, current, resistance and temperature readings are required.
The instruments meet IEC61010-1 and are rated for CATIII600V with Pollution Degree2.
Certifications include UL, CSA, CE, VDE, TUV and EN60825-1 ClassII for applicable components.
Fuse protection for the A input uses an 11A,1000V fuse with high interrupt rating for models so equipped.
Operating temperature range is -10°C to +50°C with humidity limits varying by temperature up to90% at35°C.
DC volts input impedance exceeds10MΩ with common-mode rejection >100dB at dc and >60dB at50/60Hz.
Informácie o zásobách sú dočasne nedostupné.
€ 474,00
€ 474,00 Each (bez DPH)
Calibration type
No Calibration
1
€ 474,00
€ 474,00 Each (bez DPH)
Informácie o zásobách sú dočasne nedostupné.
Calibration type
No Calibration
1
Technické Dokumenty
Špecifikácie
Brand
FlukeČíslo modelu
116/62 MAX+
Typ produktu
Sada multimetrů
Použití
Industrial
Obsah sady
Infračervené teploměry, Sondy, Pouzdro, Multimetr
Typ sady
Multimeter Kit
Normy/schválení
EN/IEC 610101: 2001, UL, CSA, EN 608251 Class II, FDA, CE, VDE, TUV
Krajina pôvodu
Malaysia
Podrobnosti o výrobku
This multimeter kit provides a portable toolkit for industrial electrical measurement and temperature checks in professional environments. Supplied with infrared thermometers, probes, a protective case and a Compact digital multimeter, it is intended for field and workshop use where voltage, current, resistance and temperature readings are required.
The instruments meet IEC61010-1 and are rated for CATIII600V with Pollution Degree2.
Certifications include UL, CSA, CE, VDE, TUV and EN60825-1 ClassII for applicable components.
Fuse protection for the A input uses an 11A,1000V fuse with high interrupt rating for models so equipped.
Operating temperature range is -10°C to +50°C with humidity limits varying by temperature up to90% at35°C.
DC volts input impedance exceeds10MΩ with common-mode rejection >100dB at dc and >60dB at50/60Hz.