Technické Dokumenty
Špecifikácie
Typ produktu
Ethernet Cable
Řada
RJ45
Délka kabelu
7m
Kategorie LAN
Cat6a
S koncovkou / Bez koncovky
Terminated
Typ pláště
S/FTP
Konektor typu A
RJ45
Konektor typu B
RJ45
Materiál pláště
Nízko dýmivý bezhalogenový
Barva pláště
Red
Normy/schválení
BS EN 50173, ANSI/TIA/EIA 568-C.2, IEC 61156-6, ISO 11801:2002, IEC 60332-1
Krajina pôvodu
Switzerland
Podrobnosti o výrobku
This Ethernet cable provides shielded network connectivity for professional installations where reduced-hazard materials and robust shielding are required. It is designed for structured cabling environments and links equipment across racks and workstations while meeting established international performance standards.
The outer jacket is formulated to emit low smoke and no halogenated gases when exposed to heat, lowering toxic fume risks for personnel and equipment.
The screened foil over each pair combined with an overall braided shield provides multi-layer protection against crosstalk and external EMI in electrically noisy environments.
It has been tested to the IEC 60332-1 protocol, assessing vertical flame propagation on single vertical insulated wires or cables.
Informácie o zásobách sú dočasne nedostupné.
€ 17,93
€ 17,93 Each (bez DPH)
1
€ 17,93
€ 17,93 Each (bez DPH)
Informácie o zásobách sú dočasne nedostupné.
1
Technické Dokumenty
Špecifikácie
Typ produktu
Ethernet Cable
Řada
RJ45
Délka kabelu
7m
Kategorie LAN
Cat6a
S koncovkou / Bez koncovky
Terminated
Typ pláště
S/FTP
Konektor typu A
RJ45
Konektor typu B
RJ45
Materiál pláště
Nízko dýmivý bezhalogenový
Barva pláště
Red
Normy/schválení
BS EN 50173, ANSI/TIA/EIA 568-C.2, IEC 61156-6, ISO 11801:2002, IEC 60332-1
Krajina pôvodu
Switzerland
Podrobnosti o výrobku
This Ethernet cable provides shielded network connectivity for professional installations where reduced-hazard materials and robust shielding are required. It is designed for structured cabling environments and links equipment across racks and workstations while meeting established international performance standards.
The outer jacket is formulated to emit low smoke and no halogenated gases when exposed to heat, lowering toxic fume risks for personnel and equipment.
The screened foil over each pair combined with an overall braided shield provides multi-layer protection against crosstalk and external EMI in electrically noisy environments.
It has been tested to the IEC 60332-1 protocol, assessing vertical flame propagation on single vertical insulated wires or cables.