Technické Dokumenty
Špecifikácie
Brand
SickTyp produktu
Input/Output Module
Řada
FLEXIL
Podtyp
Modul pro připojení Flexi Classic k IO-Link
Pro použití s
Flexi Soft System
Napájecí napětí
24V dc
Počet vstupů
2
Počet výstupů
5
Certifikace pro nebezpečné prostory
No
Normy/schválení
UL, CE
Krajina pôvodu
Hungary
Podrobnosti o výrobku
Flexi Loop can connect up to 32 safety sensors in series in compliance with the highest performance level PL e. Safety switches and safety sensors with OSSD outputs can be used together, regardless of manufacturer. Detailed diagnostic information is also available for each sensor or switch. Integrated switching signals allow for the use of interlocks, switches, and lamps. All sensors are supplied with voltage directly from the Flexi Loop. Unshielded standard cables are used with M12 male connectors. Ultimately, Flexi Loop can be relied upon for maximum safety. Connecting sensors in series reduces the amount of wiring and the number of safety inputs in the control cabinet. It also provides a comprehensive diagnostic check of all doors, emergency stop pushbuttons, and sensors. In conjunction with Flexi Soft and Flexi Classic, the entire safety application is able to cost-effectively meet customer needs.
Informácie o zásobách sú dočasne nedostupné.
€ 122,21
€ 122,21 Each (bez DPH)
1
€ 122,21
€ 122,21 Each (bez DPH)
Informácie o zásobách sú dočasne nedostupné.
1
Technické Dokumenty
Špecifikácie
Brand
SickTyp produktu
Input/Output Module
Řada
FLEXIL
Podtyp
Modul pro připojení Flexi Classic k IO-Link
Pro použití s
Flexi Soft System
Napájecí napětí
24V dc
Počet vstupů
2
Počet výstupů
5
Certifikace pro nebezpečné prostory
No
Normy/schválení
UL, CE
Krajina pôvodu
Hungary
Podrobnosti o výrobku
Flexi Loop can connect up to 32 safety sensors in series in compliance with the highest performance level PL e. Safety switches and safety sensors with OSSD outputs can be used together, regardless of manufacturer. Detailed diagnostic information is also available for each sensor or switch. Integrated switching signals allow for the use of interlocks, switches, and lamps. All sensors are supplied with voltage directly from the Flexi Loop. Unshielded standard cables are used with M12 male connectors. Ultimately, Flexi Loop can be relied upon for maximum safety. Connecting sensors in series reduces the amount of wiring and the number of safety inputs in the control cabinet. It also provides a comprehensive diagnostic check of all doors, emergency stop pushbuttons, and sensors. In conjunction with Flexi Soft and Flexi Classic, the entire safety application is able to cost-effectively meet customer needs.